TM 5-3610-293-13&P
4-27. PHASE MONITOR METER. - Continued
f.
Repair by replacing phase selector switch.
WARNING
The main power cable to the Press Section MUST be disconnected before
performing any maintenance on the phase monitor meter. Failure to do so may
result in DEATH or serious injury.
(1)
Remove phase monitor meter (1) from wall by removing screws (2), lockwashers (3) and flat
washers (4).
(2)
Tag and unsolder wires (23).
(3)
Loosen screw (24) and remove knob (25).
(4)
Remove nut (26), lockwasher (27), flat washer (28), and phase selector switch (29).
(5)
Position replacement phase selector switch (29) and secure with flat washer (28), lockwasher
(27), and nut (26).
(6)
Position knob (25) and tighten screw (24).
(7)
Solder wires (23) and remove tags.
(8)
Attach phase monitor meter (1) to shelter wall by secure flat washers (4), lockwashers (3), and
screws (2).
g.
Repair by replacing circuit board.
WARNING
The main power cable to the Press Section MUST be disconnected before
performing any maintenance on the phase monitor meter. Failure to do so may
result in DEATH or serious injury.
(1)
Remove phase monitor meter (1) from wall by removing screws (2), lockwashers (3) and flat
washers (4).
4-87