TM 5-3610-293-13&P
4-27. PHASE MONITOR METER. - Continued
c.
Repair by replacing correct/incorrect phase indicator lights.
WARNING
The main power cable to the Press Section MUST be disconnected before
performing any maintenance on the phase monitor meter. Failure to do so may
result in DEATH or serious injury.
NOTE
The procedure is the same for both phase indicator lights.
(1) Remove phase monitor meter (1) from wall by removing screws (2), lockwashers (3) and flat
washers (4).
(2) Tag and unsolder wires (11).
(3) Remove nut (12) and phase indicator light (13).
(4) Position replacement phase indicator light (13) and secure with nut (12).
(5) Solder wires (11) and remove tags.
(6) Attach phase monitor meter (1) to shelter wall by securing flat washers (4), lockwashers (3), and
screws (2).
(7) Turn on power and test operation.
d.
Repair by replacing phase test switch.
WARNING
The main power cable to the Press Section MUST be disconnected before
performing any maintenance on the phase monitor meter. Failure to do so may
result in DEATH or serious injury.
4-85