TM 5-3610-293-13&P
4-27. PHASE MONITOR METER. - Continued
(1)
Remove phase monitor meter (1) from wall by removing screws (2), lockwashers (3) and flat
washers (4).
(2)
Tag and unsolder wires (14).
(3)
Remove nut (15), lockwasher (16), and phase test switch (17).
(4)
Position replacement phase test switch (17) and secure with lockwasher (16) and nut (15).
(5)
Solder wires (14) and remove tags.
(6)
Attach phase monitor meter (1) to shelter wall by securing flat washers (4), lockwashers (3), and
screws (2).
(7)
Turn on power and test operation.
e.
Repair by replacing frequency meter.
WARNING
The main power cable to the Press Section MUST be disconnected before
performing any maintenance on the phase monitor meter. Failure to do so may
result in DEATH or serious injury.
(1)
Remove phase monitor meter (1) from wall by removing screws (2), lockwashers (3) and flat
washers (4).
(2)
Tag and disconnect wires (18).
(3)
Remove nuts (19), lockwashers (20), screws (21), and frequency meter (22).
(4)
Position replacement frequency meter (22) and secure with screws (21), lockwashers (20), and
nuts (19).
(5)
Connect wires (18) and remove tags.
(6)
Attach phase monitor meter (1) to shelter wall by securing flat washers (4), lockwashers (3), and
screws (2).
(7)
Turn on power and test operation.