TM 5-3610-295-13&P-2
5-11. MAIN POWER RECEPTACLE ASSEMBLY.
This task covers:
a.
Inspect
b.
Replace
c.
Repair
INITIAL SETUP
Tools
Electrical equipment tool kit
Materials
None
WARNING
DEATH or serious injury could result if electrical precautions are not taken when
maintaining this equipment. Use extreme caution during the disconnect process.
Disconnect the power source from power cable and disconnect cable.
a.
Inspect. (See Figure 5-2.)
(1)
Inspect main power receptacle of outside rear wall of shelter for general condition and security of
mounting.
(2)
Inspect electrical connector pins of outside rear wall of shelter for damage and corrosion.
(3)
Inspect knurled, threaded female portion of outside rear wall of shelter for thread damage and
corrosion.
(4)
Inspect protective cap and chain of outside rear wall of shelter for damage and security of chain
attachment.
(5)
Inspect electrical shield and mounting screws of outside rear wall of shelter for damage, security, and
correct sealing.
b.
Replace.
(1)
Remove receptacle access plate (1, Figure 5-2) from receptacle box (2) (inside shelter) by removing
attaching screws (3).
5-12