TM 5-3610-295-13&P-2
SECTION IV. DIRECT SUPPORT MAINTENANCE PROCEDURES
5-9.
GENERAL. The instructions contained in this section are for the use of direct support maintenance personnel
responsible for maintenance of the press shelter unit of the special warfare printing plant. Procedures for general repair
and maintenance are defined where they occur during the performance of maintenance activity covered by the various
paragraphs of this section. Maintenance procedures for the items of equipment which form a part of the shelter system
are included in the various commercial manuals supplied with the equipment.
Refer to TM 5-4120-378-14, Operator's, Organizational, Direct Support, and General Support Maintenance Manual, Air
Conditioner for direct support maintenance and repair procedure pertaining to the air conditioners.
Refer to TM 10-5411-207-14 Maintenance and Repair Procedures for Shelter, Electrical Equipment for direct support
maintenance and repair procedures pertaining to the shelter itself.
5-10. MAIN POWER CABLE ASSEMBLY.
This task covers:
a.
Inspect
b.Repair
INITIAL SETUP
Tools
Electrical equipment tool kit
Materials
None
a.
Inspect. (See Figure 5-1.)
WARNING
DEATH or serious injury could result if electrical precautions are not taken when
disconnecting this cable. Use extreme caution during the disconnect process.
Disconnect the power source from power cable and disconnect cable.
(1)
Inspect main power cable assembly of outside rear wall of shelter for deterioration of rubber
insulation.
5-9