TM 11-7025-210-23
4-56. ADJUST MAGNETIC BELT GUIDE AND REBOUND BAR (CONT)
CAUTION
Do not loosen any other screws on top of
hammerbank. They will affect a critical
factory adjustment. 14. Loosen screw on
each end of the rebound bar.
15. At one end of rebound bar, hold alignment gauge, as
shown, against groove in pulley and rebound bar.
16. Using feeler gauge, set clearance gap of 0.031 inch
(0.79 mm) between pulley and alignment gauge.
17. Snug down screw.
18. Go to other end of rebound bar. Repeat steps 15-17.
4-139