TM 11-7025-210-23
4-64.
REMOVE/REPLACE POWER SUPPLY CAPACITORS AND REACTOR (CONT)
WARNING
Capacitor may contain dangerously high
voltage.
7.
Ground capacitor.
8.
Tag, then remove wire leads.
9.
Remove screw. Pull off mounting clamp.
10.
Lift out capacitor from under other mounting
clamp.
11.
Locate reactor.
12.
Tag, then remove wire leads.
13.
steps 2-8).