TM 10-3610-202-14
4-53. Ladder.
a.
Inspection.
(1)
Inspect ladder for dents, cracks, bends or
other damage.
(2)
Ensure clamps are properly attached to
ladder, and are not severely damaged.
(3)
Replace
any
damaged
parts
as
necessary.
b.
Removal.
(1)
Unbuckle retaining strap. (See fig. 4-31.)
(2)
Lift ladder from mounting bracket and
remove ladder from wall.
c.
Repair. If ladder is to be repaired, the
procedures are as follows:
(1)
Remove dents on ladder steps.
(2)
Remove dents on clamps or replace
clamps as necessary.
d.
Installation .
(1)
Position ladder against wall and lower
onto mounting bracket.
(2)
Secure ladder with retaining strap.
Section XXV. MAINTENANCE OF LEVEL INDICATOR GAGE
4-54. General.
Two recessed level indicator assemblies are installed on
the shelter. One gage is installed on the outside rear
wall of the shelter to the left of the shelter door. The
second is installed on the outer left hand wall of the
shelter. The indicators are used to level the shelter
during installation on uneven terrain.
4-55. Level Indicator Gage.
a.
Inspection.
(1)
Inspect
the
level
gages
for
secure
mounting, broken or cracked sight glass.
(2)
Inspect for correct level indication by
placing several levels in various locations and positions
on the shelter floor and compare the headings with
those of the shelter levels.
(3)
Remove and repair as required. If
replacement of the entire assembly is necessary, notify
direct and general support maintenance.
b.
Removal. Remove the two mounting screws
and nuts that secure the gage to the mounting bracket
and remove the gage. (See fig. 4-32.)
Figure 4-32. Level Indicator Gage, Removal and Installation
4-55