TM 10-3610-202-14
Figure 4-29. First Aid Kit
4-49. First Aid Kit.
a.
Inspection. Inspect first aid kit for security and
for condition of contents. Remove and replace first aid
kit as required.
b.
Removal. Remove the first aid kit from the
shelter wall as follows:
(1)
Remove contents from the first aid kit.
(2)
Drill out four blind fasteners that secure
the first aid kit to the wall of the shelter.
c.
Installation. Install first aid kit on wall of shelter
as follows:
(1)
Remove contents of new first aid kit.
(2)
Using heavy paper, construct a mounting
hole location template by placing the paper on the
defective first aid kit and marking mounting holes.
(3)
Using the template as a guide, drill
mounting holes in the replacement first aid kit.
(4)
Install first aid kit on the shelter wall using
four blind fasteners and four existing holes in the shelter
wall.
(5)
Replace contents of first aid kit and
secure lid.
Section XXIII. MAINTENANCE OF SHELTER DOOR FILTER
4-50. General.
A removable foam-type air filter located near the center
of the shelter door permits filtered outside air to enter
the shelter when the door is closed and the hinged
weather cover, mounted on the outside of the door, is
open.
4-51. Shelter Door Filter.
a.
Inspection. Inspect the door filter as follows:
(1)
Inspect the filter for dirt which could
4-51