TM 10-3610-202-14
b.
Cleaning and Inspection Clean and inspect the
humidifier assembly as follows:
(1)
Remove humidifier front cover. Check for
proper operation of inlet valve by raising and lowering
valve arm. If necessary adjust water inlet valve for
correct opening by turning the knurled adjusting nut
above the humidifier float. (See fig. 4-26.)
CAUTION
Do not handle the large copper
disc at the rear of the unit as it
has been care fully made and
balanced to provide a smooth and
quiet
operation.
Figure 4-27. Humidifier Rear View
(2)
Where local water may have a high
mineral content, the user may experience a buildup of
scale on some surfaces of the humidifier due to
repeated wetting and drying during operation. This
scaling can be removed by cleaning with household
vinegar or a diluted solution of acetic acid (2 percent by
volume). Perform carefully to avoid distortion of large
copper disc (see fig. 4-27). Rinse the humidifier
thoroughly.
(3)
Make sure all surfaces are clean and that
the motor shaft turns freely by gently turning the small
disc.
(4)
Install humidifier front cover.
c.
Lubrication. Lubricate the humidifier assembly
as follows:
(1)
Remove humidifier front cover.
(2)
Lubricate the motor bearings every six
months at the two holes in the motor bearing caps using
a few drops of OE-10 (Lubricating Oil, Internal
Combustion Engine). For ease in application an eye
dropper is provided with the humidifier. (See fig. 4-26.)
(3)
Install
the
humidifier
front
cover.
4-48