TM 10-3610-202-14
(c)Remove screws and clamps that secure tubing to
shelter wall and front panel.
(d)
Disconnect
water
supply
line
at
connectors and remove tubing.
(e)
Close humidifier drain valve.
(3)
Installation.
(a)
Position tubing and connect water
supply line at connectors.
(b)
Position tubing on shelter wall and
secure with clamps and screws.
NOTE
Open previously closed valve at
bottom of tank to allow waterflow
to humidifier before placing unit
in operation.
(c)
If replacement of tubing is required,
bend and cut a new piece of tubing using the old tubing
as a pattern.
(d)
Place replacement compression nuts
and sleeves on each end of new tubing.
(e)
Place new tubing into position and
tighten compression nuts at connectors.
(f)
Turn on water supply at the supply
tank and check fittings for leaks. Tighten as necessary
to stop leaks.
(g)
Position tubing on shelter wall and
secure with clamps and screws.
Section XIV. MAINTENANCE OF HEADLINER COMPOSING MACHINE
4-32. General.
The Headliner photocomposing machine, installed
on the headliner counter in the right rear section of the
shelter, provides a variety of styles and sizes of display
type. For further information refer to applicable
commercial manuals.
4-33. Headliner Composing Machine.
a.
Removal. To remove the headliner composing
machine proceed as follows:
(1)
Disconnect
the
headliner
composing
machine electrical connector from the wall receptacle.
(2)
Remove the thumbscrew securing the
stop lock to the headliner counter and remove the stop
lock. (See fig. 4-21.)
4-40