Water level probe is flexible and may be bent when removing and installing.
(6) Lift tank level probe (5) out of water tank (1).
(7) Place spring holder (7) in upper part of level probe (5) and cut off new level probe (5) to same length as
old level probe (5).
(8)
Place spring holder (7) on bottom of level probe (5).
(9)
Apply RTV sealing compound (Appendix E, item 33) to rubber grommet (8).
(10) Insert new tank level probe (5) into water tank (1).
(11) Tighten bottom nut (6) on tank level probe. Do not over tighten.
(12) Connect terminal wire (4) to tank level probe (5).
(13) Tighten top nut (3) on water tank level probe (5).
(14)
Close rear door (2).
(15) Turn on power, test operation and adjust water level on water level monitor by filling tank and turning
indicator adjustment (9) to full.