TM 5-3610-293-13&P
4-22. SINK ASSEMBLY. - Continued
k.
Repair by replacing Fresh Water or Gray Water Drain Solenoid. (Figure 4-27.)
Figure 4-27. Replace Fresh Water or Gray Water Drain Solenoid
WARNING
Disconnect power to the sink assembly before opening rear door. DEATH on
contact may result if power is not disconnected.
(1) Place switch S1 (1) in OFF position.
(2) Open rear door (2).
4-69