TM 5-3610-295-13&P-2
4-10.
UNIT TROUBLESHOOTING. - Continued
TABLE 4-3. UNIT TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
WATER TANK AND MOUNTING ASSEMBLY DO NOT OPERATE PROPERLY.
Step 1. Check for blown water pump fuse.
NOTE
Fuse is located in the underside of the wire raceway above the storage bench.
Check/replace as follows:
a.
Push in on fuse holder; turn 1/4 turn counterclockwise and remove holder and fuse.
b.
Remove fuse from holder and inspect for a blown element.
c.
Install replacement fuse in holder and install in raceway by pushing in and turn 1/4 turn clockwise to
lock in place.
Step 2. Inspect water pump for security, correct electrical connection, water level, and proper operation.
Plug in pump.
Fill water tank.
Replace water pump. (See paragraph 4-18b.)
Step 3. Inspect tubing for breaks and proper connection.
Replace tubing. (See paragraph 4-18b.)
4-15