TM 5-3610-295-13&P-2
2-8. ASSEMBLY AND PREPARATION FOR USE. - Continued
j. Filling Water Tank.
(1) Connect hose to water tank connection on roadside exterior wall of shelter.
(2)
Connect other end of hose to water source and fill water tank.
(3)
Disconnect and stow hose.
k. Setting Up 15 KW Generator and Connecting Main Power Cable.
WARNING
DEATH or serious injury could result if electrical
precautions
are
not
taken
when
maintaining
this
equipment. Be sure that power cables are unplugged/
disconnected, that circuit breakers are set to OFF and that
generator cables are unplugged/disconnected. Be sure the
equipment is properly grounded. Always have another
person standing by who is familiar with electrical shock
first aid.
(1) Setting Up Generator.
(a) Set all circuit breakers in main power service box to OFF.
(b) Install ground rod and connect ground wire to ground rod and shelter
grounding point.
(c) Refer to generator TM 5-6115-464-12 for instruction on installation and operation of the generator.
WARNING
When used in conjunction with Modular Print System, only
the Modular C supervisor is authorized to operate controls
on the Power Distribution Box. Failure to follow these
procedures can cause serious injury or DEATH.
(d) Connecting Main Power Cable to Shelter. Connect the 50 foot main power cable to the input power
receptacle located near door of shelter prior to connecting cable to power source. Connect 6 foot pigtail connector to 50
foot power cable.
(1) The cable connector and receptacle are keyed to ensure proper connection.
2-14