TM 5-3610-295-13&P-1
5-11.
MAIN POWER RECEPTACLE ASSEMBLY. - Continued
b. Replace.
(1) Remove receptacle access plate (1, Figure 5-2) from receptacle box (2) (inside shelter) by removing
attaching screws (3).
Figure 5-2. Main Power Cable Receptacle
Assembly (Inside Shelter)
(2) Remove door and cover assembly (2) from main power service assembly by removing attaching screws (1).
(3) Tag and unsolder four main electrical wires of main power service assembly from terminals.
Remove