TM 5-3610-295-13&P-1
SECTION IV. DIRECT SUPPORT MAINTENANCE PROCEDURES
5-9.
GENERAL. The instructions contained in this section are for the use of direct support maintenance personnel
responsible for maintenance of the editorial shelter unit of the special warfare printing plant.
Procedures for general repair and maintenance are defined where they occur during the performance of maintenance
activity covered by the various paragraphs of this section. Maintenance procedures for the items of equipment which
form a part of the shelter system are included in the various commercial manuals supplied with the equipment.
Refer to TM 5-4120-378-14, Operator's, Organizational, Direct Support, and General Support Maintenance Manual, Air
Conditioner, or TM 5-4120-340-14, Organizational, Direct Support, and General Support for direct support maintenance
and repair procedure pertaining to the air conditioners.
Refer to TM 11-5410-213-14P-1 and TB 43-0124, Maintenance and Repair Procedures for Shelter, Electrical Equipment
for direct support maintenance and repair procedures pertaining to the shelter itself.
MAIN POWER CABLE ASSEMBLY.
This task covers:
a. Inspect
b. Repair
INITIAL SETUP
Tools
Electrical equipment tool kit
Materials
None
WARNING
DEATH or serious injury could result if electrical precautions are not taken when disconnecting
this cable. Use extreme caution during the disconnect process. Disconnect the power source
from power cable and disconnect cable.