TM 5-3610-295-13&P-1
4-18. VERTICAL CAMERA AND MOUNTING ASSEMBLY. - Continued
b. Replace. - Continued
(i) Install floor mounting bracket (13) on replacement camera (9) by securing flat washers (12),
(j) Install wall mounting brackets (17) on replacement camera (9) and secure with flat washers (16),
WARNING
Serious injury could result if heavy equipment is moved/lifted
without sufficient personnel. Use a suitable lifting device/dolly if
possible or have sufficient personnel available for the task to
prevent injury to personnel.
(k)
Lift replacement camera (9) and position in front of floor shock mounts (20).
(l)
Lift replacement camera (9), rotate 900, and position mounting bracket over floor shock mount
(20) holes.
(m) Install floor shock mount nuts (8) and bolts (7).
(n)
Install upper shock mount nuts (6) and bolts (5).
NOTE
Vacuum pump receptacle is keyed for a twist lock plug.
(o)
Connect vacuum pump power cord (1) and vacuum hose (4).
(p)
Connect light bar power cord (2) and camera power cord (1).
4-41