GENERAL. - Continued
Table 3-1. Operator Troubleshooting - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 4. Check door latches for proper operations and for broken or missing parts.
Notify unit maintenance of trouble.
6. CEILING LIGHT ASSEMBLY DOES NOT OPERATE.
Step 1. Ensure that fluorescent light bulbs operate when switch in ON.
Replace light bulbs. (Refer to paragraph 3-7.)
Step 2. Check light assembly for dents and for loose or missing hardware.
Notify unit maintenance of trouble.
Step 3. Check light assembly power cord for frayed or broken insulation.
Notify unit maintenance of trouble.
7. SINK ASSEMBLY DOES NOT OPERATE PROPERLY.
Step 1. Check operator controls and indicators for proper operation and for loose or missing hardware.
Notify unit maintenance of trouble.
Step 2. Inspect sink assembly power cord for frayed or broken insulation.
Notify unit maintenance of trouble.
Step 3. Check transporter assembly for ease of operation.
Lubricate transporter assembly wheels.
3-8