TM 5-3610-293-13&P
2-13. INTRODUCTION. - Continued
Table 2-1. Operator Preventive Maintenance Checks and Services (PMCS) (Cont.)
B - Before
D - During
A - After
Interval
Item
Item To Be Inspected
Equipment is not
No.
B
D
A
Procedure
Ready/ Available if:
1
Power Distribution Panel -
Damaged, missing or loose
Visual Inspection
WARNING
High Voltage exists in the
electrical system of this
equipment. DEATH on
contact may result if personnel
fail to observe safety
precautions.
1.
Inspect for damage to door
Door or panel damaged.
and panel.
2.
Inspect circuit breakers for
Circuit breakers not
operation, condition
and operating.
security.
2
Emergency Light - Check
operation of light.
1.
Test battery by operating
Lights do not operate when
test switch with ON/OFF
test switch is activated.
switch in ON position.
2.
Check Ready light.
Ready light does not
operate when circuit
breaker switch is turned
ON.
3.
Check light bulbs for
Lights do not operate when
operation with ON/OFF
test switch is activated.
switch in ON position.
2-20