TM 5-3610-293-13&P
4-14.
AIR CONDITIONER ASSEMBLY.
(1)
Place air conditioner circuit breaker on power distribution panel in OFF position.
WARNING
Never connect or disconnect any power cables when electrical power is
energized to the cables. Failure to do so will result in damage to equipment
and/or serious injury or DEATH to personnel.
(2)
Open cargo doors (1) and disconnect door holder bracket (2).
(3)
Remove screws (3).
(4)
Loosen quick release (4) and remove access cover (5).
(5)
Remove filter (6).
(6)
Remove screws (7) and electrical cover (8).
(7)
Tag and disconnect thermostat wires (9).
(8)
Tag and disconnect grounding wires (10).
(9)
Tag and disconnect main power wires (11).
(10)
Remove tie straps (12).
(11)
Pull electrical cables out and away from air conditioner assembly.
(12)
Remove screws (13) and intermediate duct (14).
(13)
Remove nuts (15), lockwashers (16), flat washers (17), bolts (18), and angle brackets (19).
(14)
Remove tie straps (20) and disconnect tee connector (21) from drain hose (22).
(15)
Working inside shelter, remove screws (1, Figure 4-4), front vent door (2), and shim (3).
(16)
Remove filter (4).
(17)
Remove filter support (5).
(18)
Remove six nuts (6), lockwashers (7), flat washers (8) and bolts (9).
4-27