TM 10-3610-203-14
Table 4-2. Troubleshooting
Malfunction
Test or Inspection
Corrective Action
SHELTER SYSTEM AND COMPONENTS
1. UNABLE, TO DUPLICATE SECOND COLOR
Step 1. Check for incorrect color press ink and water adjustment.
Adjust for correct ink and water flow in accordance with commercial manual instructions.
Step 2. Check color press for damage or defects.
If necessary, replace defective color press as described in paragraph 4-19.
2. NO WATER AT FAUCET
Step 1. Inspect for lack of water in storage tank.
If necessary, fill water storage tank u follows:
a. Check that all valves in the water line are closed.
b. Remove the tank filler cap located on the root of the shelter.
c. Fill the. tank to its full capacity of approximately 10 gallons (37.8 liters) with clean water, and
replace the filler cap.
d. Open the humidifier supply valve (see fig. 4-3) allowing the humidifier water tank to fill to its
preset level.
4-14