TM 10-3610-203-14
Table 4-1. Organizational Preventive Maintenance Checks and Services - Cont
Legend
W - Weekly
Q - Quarterly
A - Annually
H - Hours
M - Monthly
S - Semiannually
B - Biennially
MI - Miles
For Readiness
Interval
Reporting.
Item
W
M
Q
S
A
B
H
MI
Item To Be
Equipment is Not
No.
Inspected
Procedures
Ready/Available If:
8
Shelter Door Filter -
Unscrew the interior
Cont
thumbscrews until the filter
frame is released.
Remove the filter and
frame assembly from the
outside of the door.
Remove the door air filter
by pulling the foam material
from the frame.
Clean the filter material by
washing in a soap and water
solution. Dry thoroughly
and spray with air filter
coater (Item 2, App. D).
Insert the foam material
under the bottom lip of the
filter frame. Tuck in the
remaining sides of the
filter under the other three
lips of the frame.
Position the frame assembly
from the outside of the door
and secure the interior
thumbscrews.
Release the bracket hinged
weather cover retaining rod
and close weather cover.
Secure the weather cover
fasteners.
9
Level Indicator Gages
Inspect the level gages for
secure mounting, broken or
cracked sight glass. If
inspection indicates that
replacement of the level
gages is necessary, refer to
paragraph 4-39.
10
Fluorescent Lamps
Inspect lamp for correct
illumination. If inspection
indicates that replacement of
the lamp is necessary, refer
to paragraph 4-41.
4-11