TM 10-3610-202-14
(2)
Repair. Repair of the upper mounting
bracket consists-of replacement.
(3)
Installation. Install the upper mounting
bracket as follows: (a) Using heavy paper, construct
mounting hole location templates by placing the paper
on the removed backing plate and upper bracket and
marking mounting holes.
(b) Using the templates as guides, drill
mounting holes in the replacement backing plate and
upper bracket. Secure backing plate and upper bracket
to the shelter with five nuts, bolts and washers utilizing
existing holes in the shelter and seal around the edges
of the bracket.
(c) Position ladder on ladder mounting
brackets and secure the retaining strap.
d. Retainer Brackets.
(1)
Removal Remove the retainer brackets as
follows:
NOTE
Replacement
procedures
are
identical
for
both
retainer
brackets.
(a) Unlatch the retaining strap and lift
ladder off ladder mounting bracket assembly.
(b) Remove two bolts, nuts, and
washers attaching the retainer, cut away sealant, and
remove retainer and mounting plate. (See fig. 15-1.)
(2)
Repair. Repair of the retainer brackets
consists of replacement.
(3)
Installation. Install the retainer brackets
as follows:
(a) Match drill the replacement retainer
with the existing retainer, position mounting plate and
secure to the shelter wall with two nuts, bolts and
washers utilizing existing holes in the shelter wall.
(b) Apply sealant around edges of
bracket.
(c) Position
ladder
on
mounting
brackets and secure the retaining strap.
15-3/(15-4 blank)