TM 5-3610-295-13&P-2
4-30. CEILING LAMP ASSEMBLY. - Continued
b.
Replace. - Continued. (See Figure 4-26).
(8)
Install upper half of light fixture (6) with rivets (7).
(9)
Connect lamp assemblies to electrical supply wires, remove tags, and secure with wire nuts (4).
CAUTION
Use care not to trap or pinch any electrical wires between the two
fixture halves.
(10)
Position lower half of light fixture (5) to upper half of fixture (6) and secure with screws (3).
(11)
Position starter (2) in socket and carefully rotate clockwise until it locks.
(12)
Position lamp tube (1) below socket receptacles with pins vertical. Insert lamp into sockets and twist
until pins lock.
(13)
Set circuit breaker on power distribution panel to ON and test by operation.
c.
Repair. (See Figure 4-26.)
NOTE
Substitute a questionable component with a new one to isolate the
cause of malfunction.
Repair of the fluorescent lamp assemblies consists of replacement of the lamp and starter only. Refer
to paragraph b. above.
4-69