TM 5-3610-295-13&P-1
5-11.
MAIN POWER RECEPTACLE ASSEMBLY. - Continued
b. Replace. - Continued
(7) Remove receptacle box (9) from shelter wall.
(8) Remove data plate (10) (power requirements) from receptacle box by drilling out rivets (11).
(9) Position data plate (10) (power requirements) on receptacle box, match drill holes, and secure with rivets
(11).
(10) Position receptacle box (9) in shelter wall opening and secure with rivets (8).
(11) Install main power receptacle (5), cap (7), and gasket (6).
(12) Install screws (4), flat washers (3), lockwashers (2), and nuts (1).
(13) Install conduit bushing (5, Figure 5-2) and conduit nut (4).
(14) Solder four main electrical wires to terminals in the main service assembly. Install tie wraps as necessary.
(15) Position receptacle access plate (1, Figure 5-2) on receptacle box (2) and secure with screws (3).
(16) Position door and cover assembly (2, Figure 5-4) on service box and secure with attaching screws (1).
c. Repair. (See Figures 5-2 and 5-3.)
Repair of the main power receptacle consists of replacement of receptacle and cap, gasket, and wiring as
necessary.
5-15