TM 5-3610-295-13&P-1
5-10.
MAIN POWER CABLE ASSEMBLY. - Continued
a. Inspect. - Continued (See Figure 5-1.)
(1) Inspect main power cable assembly of outside rear wall of shelter for deterioration of rubber insulation.
(2) Inspect main power cable assembly for general condition of insert, barrel, cable adapter, and protective cap.
(3) Inspect metal parts of main power cable assembly for corrosion.
b. Repair. (See Figure 5-1.)
(1) Loosen the connection on the main power cable assembly between the female barrel (1) and cable adapter
(2) and separate unit.
(2) Separate the female barrel (1) and female insert (3) on the main power cable assembly.
(3) Install female barrel (1) and female insert (3) of the main power cable assembly in the threaded portion of the
cable adapter (2) and tighten.
5-10