TM 5-3610-295-13&P-1
3-3. GENERAL. - Continued
Table 3-1. Operator Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Inspect to see if equipment circuit breaker is in the ON position.
Position applicable circuit breaker to ON.
3. LIGHT TABLE WILL NOT ILLUMINATE.
Check for defective fluorescent tube.
4. CAMERA VACUUM COPYBOARD INOPERATIVE.
Turn on vacuum pump and check for leaks from vacuum hose extending from pump to underside of copyboard.
Disconnect defective hose at pump and copyboard and replace hose as described in TM 5-3610-303-12&P.
5. NO WATER FROM FAUCET.
Step 1. Check to see if there is water in tank.
Fill water tank.
Step 2. Check to see if the proper circuit breaker in main panel for the water pump is in the ON position.
Position applicable circuit breaker to ON.
6. TEMPERATURE IN SHELTER TOO HOT OR TOO COLD.
Step 1. Check thermostat for proper setting.
Set thermostat to proper temperature.
3-5