TM 5-3610-294-13&P
4-10. UNIT TROUBLESHOOTING. - Continued
Table 4-2. Unit Troubleshooting (Cont.)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
EMERGENCY LIGHT DOES NOT OPERATE PROPERLY. - CONT.
Step 2.
Check that emergency light is plugged into wall outlet.
Plug in emergency light.
Step 3.
Check that test circuit breaker in power distribution panel is set to ON.
Set circuit breaker to ON.
Step 4.
Remove fuse and check for continuity.
Replace fuse on circuit card.
Step 5.
Unplug emergency light, check for broken wires, and test ON/OFF switch for continuity.
Replace wiring or switch (Paragraph 4-26b(2).)
Step 6.
Test battery for an open.
Replace battery (Paragraph 4-26b(3).)
If good, replace emergency light (Paragraph 4-26a).
b.
Emergency light does not light when tested and charge light is lit.
Step 1.
Wait 20 minutes or until charge light starts to flicker and test.
Replace battery (Paragraph 4-26b(3).)
10.
LIGHT TABLE ASSEMBLY DOES NOT OPERATE PROPERLY.
Step 1.
Inspect light table for security of mounting.
Mount light table (Paragraph 4-28.2b).
Step 2.
Check glass top for cracks or breaks.
Replace glass top (Paragraph 4-28.2c).
Step 3.
Check fluorescent tubes for proper operation.
Replace fluorescent tubes (Paragraph 4-28.2c).
Step 4.
Inspect operation of ON and OFF switch.
Replace switch (Paragraph 4-28.2c).
Change 1
4-17/(4-18 Blank)