TM 5-3610-294-13&P
4-28.2 LIGHT TABLE ASSEMBLY. - Continued
c.
Repair. (See Figure 4-32.)
(1)
Remove three screws (1) and alignment rail (2).
(2)
Remove plastic top (3) and table glass (4).
(3)
Grasp fluorescent tubes (5), rotate 90°, and remove from tube sockets.
(4)
Rotate starters (6) counter clockwise and remove from sockets.
(5)
Remove nuts (7) and remove ballasts (8).
(6)
Remove power cord (9), switch (10), and nut (11).
(7)
Remove nuts (12) and remove left and right lamp bracket assemblies (13).
(8)
Install left and right lamp bracket assemblies (13) and secure with nuts (12).
(9)
Install switch (10), nut (11), and power cord (9).
(10)
Install ballasts (8) and secure with nuts (7).
(11)
Install starters (6) by inserting and turning clockwise.
(12)
Install fluorescent tubes (5) by rotating 90° in sockets.
(13)
Install table glass (4) and plastic tap (3).
(14)
Install alignment rail (2) and secure with three screws (1).
(15)
Align rail square to other rails using T-square.
Change 1 4-73