Table 4-1. Organizational Preventive Maintenance Checks and Services
Legend
W - Weekly
Q - Quarterly
A-Annually
H - Hours
M - Monthly
S - Semiannually
B - Biennially
MI - Miles
For Readiness
Interval
Reporting
Item
Item To Be
Equipment is Not
No.
W
M
Q
S
A
B
H
MI
Inspected
Procedures
Ready/Available If:
1
Water Supply
Inspect draincock, faucet,
Plumbing
lined and fittings for damage
which could cause leaks. If
Inspection indicates that
replacement of plumbing
components is necessary,
refer to paragraph 4-31.
2
Air Conditioner Air
Inspect for cleanliness,
Intake Filter
damage and proper install-
ation as follows:
(1) Remove the eight
screws attaching the louver
to the shelter exterior
wall.
(2) Remove the louver
and gasket.
(3) Pull out filter and
grills from louver frame.
(4) Clean filter by wash-
ing in a soap and water
solution. Dry thoroughly
and spray with coater
(NSN 4130-00-860-0042).
(5) If filler is damaged,
replace with new filter.
(6) Install filter by
inserting filter and grills
into louver frame.
(7) Position gasket and
louver on shelter wall.
(8) Secure with eight
attaching screws.
3
Fire Extinguisher
Inspect nozzle and adapter
assembly for security and
condition. Weigh cylinder
every six months and re-
place if gross weight has
decreased by six ounces
(17.0 gm) or more. If
Inspection indicates 'that
replacement of the fire
extinguisher Is necessary,
refer to paragraph 4-47.
4-8 Change 1