TM 5-3610-295-13&P-1
4-8. GENERAL. - Continued
Table 4-2. Unit Preventive Maintenance Checks and Services - Continued
Item
Interval
Item Inspected
Procedures
No.
M
Q
S
8
Wall Mounted
Inspect viewing light for general
Viewing Light
condition and security of mounting. If
inspection indicates replacement is
necessary, refer to paragraph 4-27.
9
Pin Point Light
Inspect light assembly for security of
Source Assembly
mounting. Inspect light assembly
casing for damage. Inspect power cord
and timer for proper operation. If
inspection indicates replacement is
necessary, refer to paragraph 4-28.
10
Phototypesetter
Inspect processor and shelf for general
Processor
condition and security of mounting. If
Assembly
inspection indicates replacement is
necessary, refer to paragraph 4-29.
11
Fire Extinguisher
Inspect nozzle and gauge for security
and condition. Weigh cylinder every 6
months and replace if gross weight has
decreased by 6 ounces (170 gm) or
more. If inspection indicates
replacement, refer to paragraph 4-31.
12
Fresh Filter
Inspect for cleanliness, damage, and
proper installation. Clean filter as
indicated in paragraph 4-35.
13
Ladder Assembly
Inspect for damage and ensure that
mounting bracket and holddown
assembly are properly attached and are
not damaged. If inspection indicates
replacement is necessary, refer to
paragraph 4-40.
4-9