TM 5-3610-295-13&P-1
5-13.
RIGID CONDUIT ASSEMBLY. - Continued
b. Repair. - Continued
(f) Remove receptacle clips (1, figure 5-7).
Figure 5-7. Receptacle Clips
(g) Install and secure conduit channel (6, Figure 5-6) with rivets (4).
(h) Install and secure corner bracket (5) with screws (3) and rivets (4).
(i) Install receptacle clips (1, Figure 5-7), cover (2, Figure 5-6), clips (1) and bushing (1, Figure 5-5).
5-21