TM 5-3610-295-13&P-2
4-18. WATER TANK AND MOUNTING ASSEMBLY. - Continued
b.
Repair. - Continued
(c) Remove bolts (4), lockwashers (5), flat washers (6), and water tank (3).
(d)
Remove fittings (7) and drain petcock (8).
(e)
Apply RTV sealant to pipe threads of drain petcock (8) and fittings (7) and install in replacement
water tank (3).
(f)
Install water tank (3) and secure with flat washers (6), lockwashers (5), and bolts (4).
(g)
Install tubing (2) and secure with clamps (1).
(h)
Install water pump. Refer to b(1) above.
(i)
Test operate water tank and check for leaks.
Figure 4-9. Water Tank Assembly
4-33