TM 5-3610-295-13&P-2
4-18. WATER TANK AND MOUNTING ASSEMBLY. - Continued
a.
Inspect. - Continued (See Figure 4-8.)
(3)
Inspect water pump for completeness, security, electrical connect, water level, and proper operation.
(4)
Inspect water tubing for breaks and proper connections.
b.
Repair. (See Figure 4-8.)
(1)
Replace pump.
(a)
Drain water tank.
(b)
Unplug power cord (1).
(c)
Remove clamps (2) and tubing (3).
(d)
Loosen bolts (4) and remove pump (5).
(e)
Remove fittings (6) from pump (5).
(f)
Wrap pipe threads with teflon tape (49, Appendix E) on replacement pump (5) and install fittings
(6).
(g)
Install replacement pump (5) and tighten bolts (4).
(h)
Install tubing (3) and secure with clamps (2).
(i)
Connect power cord (1) and fill water tank.
(j)
Test operate water pump.
4-31