TM 11-7025-210-23
4-66. REMOVE/REPLACE RUN/LOAD SWITCH
(CONT)
Replace
1.
Push on switch. Push on plate.
2.
Replace screws. Do not tighten.
3.
Solder wires to switch. Push sleeving over
4.
Check switch.
If switch arm does not touch lever, as shown,
go to step 6
If switch arm touches lever, go to step 5
5.
Move screws in direction shown until switch arm
does not touch lever. Go back to step 4.
4-164